SK30G-3200 INVERTER
Product Detailed
Related Categories:Inverters & Converters
They boast high precision, low noise emission, large torque, reliable performance, etc.
Product General Specification
Name of Project | SK-G/P/Z/M | |
Modes of Control | SPWM Space Vector Voltage Control | |
Input Power | 380 V power: 340-430 voltage; 220 V power: 180-250 V | |
Five Digital Display and Status of Indicator Lamp | Display frequency, current, rotation speed, voltage, counter, direct current voltage, output voltage, feedback pressure, set pressure, temperature, status of reversal rotation, fault, etc. | |
Telecommunication Control | RS-485 | |
Operation Temperature | -10~40°C | |
Humidity | 0-95% relative humidity (No condensation) | |
Vibration | Below 0.5G | |
Frequency Control | Range | 0.01~400.00Hz |
Precision | Digital type: 0.01%(-10~40°C); simulate type: 0.1%(25±10°C) | |
Set Resolution | Digital type: 0.01Hz; simulate type: 1% of the largest operation frequency | |
Output Resolution | 0.01Hz | |
Keyboard Setting Mode | You can set directly , you can also set with panel potentiometer.) | |
Simulation Setting Mode | External voltage0~5V, 0~10V, 4~20mA,0~20mA | |
Other Functions | Top and bottom limits of frequency, starting frequency, stopping frequency, and three hopping frequencies can be set separately. | |
General Control | Control of Acceleration and Deceleration | Four sections of acceleration and deceleration time (0.1 ~ 6500 s) are available for free choice |
V/F Curve | V/F curve can be set freely | |
Torque Control | You can set the torque promotion with the maximum 10.0%, and it can reach 150% when the starting torque is 1.0Hz. | |
Energy-saving Control | Regulate the output voltage automatically according to the load, which makes the working efficiency of motor even higher. | |
PID | PID Function is set inside | |
Simple PLC | It can make up automatic control and the operation time and mode can be set freely. | |
Multi-function Input | Six multi-function inputs realize the control of 8-section speed, program operation, shift of 4-section acceleration and deceleration, UP, DOWN function, counter, external emergency stop, etc. | |
Multi-function Output | Five multi-function outputs realize the indication and alarm of zero speed, counter, external abnormality, program operation, etc, in the progress of operation. | |
Other Functions | Automatic voltage regulator(AVR), deceleration stop or free stop, direct current brake, automatic reset and start, frequency tracking, PLC program control, traverse control, drawing control automatic energy-saving operation, carrier wave adjustability (with the maximum 20KHz), etc. | |
Protective Function | Overload Protection | Electronic circuit protection motor driver (constant torque 150% for one minute, wind machine type 120% for one minute). |
FUSE Protection | Once the use is blown, the motor will stop working immediately. | |
Low Voltage | 220 V Line: Direct Current Voltage<200 V 380 V Line: Direct Current V<400 V | |
Excess Voltage | 220 V Line: Direct Current Voltage<400V 380V Line: Direct Current Voltage<800 V | |
Instantaneous Stop and Restart | Restart by frequency tracking after instantaneous stop. | |
Stall Prevention | Stall prevention in the operation of acceleration and deceleration. | |
Output Short Circuit | Electrical circuit protection | |
Other Functions | Overheat protection for heat sink, reverse limitation, direct start of the fault reset function after starting the machine, parameter lock, etc. |
SK30G-3200 INVERTER