LCD online UPS

LCD online UPS
Product Detailed
Generator setting function ECO,EPO option USB, RS232,RJ11 option Optional SNMP Card slot LCD or LED displayl

           
Model
SKG-V1KSKG-V1KSSKG-V2KSKG-V2KSSKG-V3KSKG-V3KSSKG-V4KSKG-V4KSSKG-V6KSKG-V6KS
Specifications
Capacity(VA/W)1000VA/700W2000VA/1400W3000VA/2100W4000VA/2800W6000VA/4200W
INPUT Feature
Battery voltage(Vdc)244896120144
Voltage Range(Vac)176~286VAC @ full load (138~300VAC @ half load)
Frequency Range(Hz)46 ~ 54Hz / 56 ~ 64Hz
Number of phasessingle phase&earth ground
Power Fator≥0.98, Full RCD Load
Generator InputSupport
Output feature
Voltage220/230/240VAC± 1%
Frequency ( Battery Mode )50/60Hz ± 0.1 Hz
Frequency(Hz)50±0.2% (battery mode)
Wave formPure Sine wave THD<4%
Overload Capacity(Line Mode)>=110%; 2mins, Then transfer to bypass and Alarm,   >=150%; 10 S, Then transfer to bypass, turn off output after 1mins and Alarm
Overload capacity( Battery Mode )> =110 %; 30 S, Then turnoff output and Alarm,  > =120 %; 1S, Then turnoff output and Alarm
Output modeIEC x2IEC x4IEC x4 Terminal BlockTerminal Block
Battery
Battery Type12V/9AHDepending on the capacity of external batteries12V/9AHDepending on the capacity of external batteries12V/5AHDepending on the capacity of external batteries12V/4.5AHDepending on the capacity of external batteries12V/9AHDepending on the capacity of external batteries
Numbers of Batteries2481012
Backup Time (Half Load)>10 min>10 min>10 min>10 min>12 min
Recharge Time (to 90%)5 Hours5 Hours3Hours3 Hours3Hours
Charging Current (Max.)1.0A3.0A1.0A3.0A2.0A6.0A2.0A6.0A2.0A6.0A
Rated Charging Voltage26.9~27.9vdc53.6~55.5vdc108~111vdc134 ~137Vdc161 ~164Vdc
Other feature
EFFICIENCY(AC /Battery Mode)93%-92%
TRANSFER TIME(AC to DC)Zero
TRANSFER TIME(Inverter to Bypass)4ms (Typical )
AUDIBLE ALARM(Battery Mode)Sounding every 4 seconds
INDICATOR(LED Version)Load Level / Battery Level / Battery Mode / AC Mode /  Bypass Mode / Fault
INDICATOR(LCD Version)Load / Battery / Input / Output / Operating Mode Information
ProtectionsLow battery protection,overload protection,short-circuit protection,overheated protection
Ambient temperes0-40
Reative humidity0-95% no condensation
Products  Size(mm)145×220×355190×318×383190×318×433260×483×573260×570×717